Overhead insulated aluminum stranded wire-(ACSR, ASC)
Aluminum stranded overhead cable (AAC) is a power transmission cable made of pure aluminum conductors, which is widely used in medium and low voltage overhead power transmission lines. The cable is light, has good conductivity and strong corrosion resistance, and is particularly suitable for urban power distribution systems and long-term overhead power lines.
Share:
Conductor:
High purity oxygen-free aluminum
Low cost
Light weight
Easy to construct
Application:
These cables are widely used for the power distribution lines with short distance and small load-carrying capability of the pole. The AAC is a good choice for overhead power transmission and distribution systems. This standard covers hard drawn copper conductor using for electric purposes and aluminum conductor steel reinforced.
Advantage:
Efficient power transmission
Aluminum stranded overhead cables adopt a trapezoidal aluminum strand design, which not only improves the power transmission efficiency, but also reduces the power loss of the line.
Lightweight and durable
Using pure aluminum as the conductor, the lightweight characteristics of aluminum stranded cables reduce the transportation and installation costs of cables, and are particularly suitable for the construction of large-scale overhead power systems.
Excellent corrosion resistance
Aluminum as a conductor will naturally form a dense aluminum oxide film on the surface, which can effectively isolate external moisture, oxygen and other corrosive substances, thereby effectively preventing corrosion.
High cost-effectiveness
Compared with copper conductor cables, aluminum stranded overhead cables have a higher cost-effectiveness. Lightweight and good conductivity ensure that while reducing costs, it meets the needs of efficient and reliable power transmission.
Technical Data
Nominal Cross Section | Structural Root Number/Diameter | Cable Outer Diameter | DC Resistance | Breaking Force | Weight |
(mm²) | (mm) | (mm) | ( ≤Ω/km) | (N) | (kg/km) |
16 | 7/1.70 | 5.1 | 1.802 | 2340 | 43.5 |
25 | 7/2.15 | 6.5 | 1.127 | 4355 | 69.6 |
35 | 7/2.50 | 7.5 | 0.8332 | 5760 | 94.1 |
50 | 7/3.00 | 9 | 0.5786 | 7930 | 135.5 |
70 | 7/3.60 | 10.8 | 0.4018 | 10950 | 195.1 |
95 | 7/4.16 | 12.5 | 0.3009 | 14450 | 260.5 |
120 | 19/2.85 | 14.3 | 0.2373 | 19420 | 333.5 |
150 | 19/3.15 | 15.8 | 0.1943 | 23310 | 407.4 |
185 | 19/3.50 | 17.5 | 0.1574 | 28440 | 503 |
210 | 19/3.75 | 18.8 | 0.1371 | 32260 | 577.4 |
240 | 19/4.00 | 20 | 0.1205 | 36260 | 656.9 |
300 | 37/3.20 | 22.4 | 0.09689 | 46850 | 820.4 |
400 | 37/3.70 | 25.9 | 0.07247 | 61150 | 1097 |
500 | 37/4.16 | 29.1 | 0.05733 | 76370 | 1387 |
630 | 61/3.63 | 32.7 | 0.04577 | 91940 | 1744 |
800 | 61/4.10 | 36.9 | 0.03588 | 115900 | 2225 |
Expand all
Only some product parameters are displayed. For more product information, please contact us.
The above parameters are for reference only.
Cable Structure
Overhead insulated aluminum stranded wire-(ACSR, ASC)
Features
Features
Conductor: AL round wire
Standard: BS215, IEC61089
Insulation: non-insulated
Range of application: overhead power transmission and distribution
No or strands: 7 strands, 19strands,37 strands and 62 strands
Conductor material: Aluminum stranded wire (AAC)
Rated voltage: 0.6/1kV or 10kV
Maximum operating temperature: 70℃-90℃
Maximum short-circuit temperature of conductor: 160℃ (short-circuit time does not exceed 5 seconds)
Laying temperature: not less than -20℃
Standard certification: IEC 61089, BS 215, GB/T 1179
Test voltage:
Aluminum stranded wire overhead cables with rated voltage of 0.6/1kV should withstand a voltage test of 3500V for 1 minute.
Aluminum stranded wire overhead cables with rated voltage of 10kV should withstand a voltage test of 18kV (12kV for light type) for 1 minute.
Production
Production Equipment
Experimental Equipment
Projects
COMMON QUESTIONS
SHENXING Cable Service FAQs
Want to learn more? Check out our electrical cable most frequently asked questions.
What are the application scenarios for aluminum stranded overhead cables?
Aluminum stranded overhead cables are widely used in urban and rural power transmission and distribution networks, especially for low and medium voltage overhead power lines. It is commonly used in distribution systems, transmission lines, substations, and some industrial power facilities, and is particularly suitable for long-distance power transmission.
What are the advantages of aluminum stranded overhead cables?
The main advantages of aluminum stranded overhead cables are their lighter weight and lower cost. Although aluminum is not as conductive as copper, it is sufficient to meet most power transmission needs. In addition, the flexibility of aluminum stranded wire makes it easier to install, especially in environments where long-distance installation is required.
What is the rated voltage of aluminum stranded overhead cables?
The rated voltage of aluminum stranded overhead cables is usually 0.6/1kV, which is suitable for low and medium voltage power systems. In some high-voltage applications, models with a rated voltage of 10kV can also be selected to select the appropriate cable specifications according to power transmission requirements.
How to ensure the installation safety of aluminum stranded overhead cables?
When installing aluminum stranded overhead cables, it is necessary to ensure that the bending radius of the cable meets the standard requirements to avoid excessive bending that causes cable damage. And use appropriate tools and methods, such as professional cable clamps and fixtures, to ensure the stability and safety of the cable during operation.
What is the temperature resistance of aluminum stranded overhead cables?
The temperature resistance of aluminum stranded overhead cables usually depends on the insulation material. Aluminum stranded cables insulated with polyvinyl chloride (PVC) usually have a temperature resistance of 70°C; while aluminum stranded cables insulated with cross-linked polyethylene (XLPE) can reach a temperature resistance of 90°C, which is suitable for a wider range of working environments.
What is the corrosion resistance of aluminum stranded overhead cables?
Aluminum stranded overhead cables have excellent corrosion resistance, especially in environments with moisture, salt spray or heavy pollution, and can maintain good electrical performance. Aluminum conductors themselves have natural corrosion resistance, and external insulation materials such as cross-linked polyethylene (XLPE) or polyvinyl chloride (PVC) further enhance their durability in harsh environments.
More Frequently Asked Questions.