Home > Wire Cable > Overhead Power Cable > Low Voltage Insulated Aerial Cable > 10kv Cross-Linked Polyethylene Insulated Overhead Cable

10kv Cross-Linked Polyethylene Insulated Overhead Cable

Insulated Aerial Cable-JKYJ

Overhead cables are mainly used for power transmission and distribution in power systems. Overhead cables are installed on poles, along roads and around buildings to transmit and distribute electrical energy. Compared with bare wires, they have the advantages of small laying span, high safety and reliability, and good resistance to atmospheric aging. Overhead cables are widely used in cities, rural areas and industrial areas.

Widely Use:

Overhead Power Distribution Systems

Our cables are widely used in overhead power distribution systems, especially in areas where underground cables are difficult to lay.

Rooftop Solar Systems

Applicable to solar photovoltaic (PV) power systems, our cables connect solar panels with inverters and energy storage systems, ensuring efficient and safe energy transmission in solar systems.

Industrial and Commercial Power Transmission

Applicable to industrial parks, factories and commercial buildings, our copper core polyethylene insulated overhead cables ensure reliable power transmission to meet high-load power demands.

Street Lighting and Traffic Signal Systems

Commonly used in street lighting and traffic signal systems, our cables are designed to withstand outdoor exposure and continuously provide power to critical infrastructure.

Advantage:

High voltage capability

Our 10kV XLPE insulated overhead cables are designed for overhead power transmission systems with rated voltages up to 10kV, suitable for power distribution networks in urban and rural areas.

Superior insulation materials

The insulation layer of the cable uses cross-linked polyethylene (XLPE) to ensure that the cable can work for a long time in harsh environments while providing optimal electrical isolation performance.

Temperature resistance

The minimum laying temperature of our cables is **-20°C**. The cables are designed for overhead laying, providing safety and convenience.

Mechanical strength and durability

The conductor uses a compact round stranded copper or aluminum conductor. This design reduces the risk of damage to the cable during installation or under external mechanical stress, ensuring long-term stable operation of the cable.

Technical Data

Number of conductorsConductor DiameterNominal AreaInsulation ThicknessCable Outer Diameter Cable WeightCable Breaking ForceMaximum Resistance of Conductor
(20℃)
Current Carrying Capacity(A)

(mm)(mm2)(mm)(mm)(kg/km)(N)Ω/kmCopper CoreAluminum Core、Aluminum alloy core





JKVJKY JKYJJKLV JKLHVJKLY JKLYJ JKLHY JKLHYJHard copperAluminumAluminum AlloyHard copperSoft copperAluminumAluminum AlloyPVCPEXLPEPVCPEXLPE
Single core3.81015.811410851453471165025141.9061.833.082.574656585505065
4.8161.27.218117279705486251740221.1981.151.912.2178990122697095
6.2251.28.4260251109978465376362840.7490.7271.21.3931201241669397128
7.2351.49.837735215113611731517788000.540.5240.8681.007148152204115118158
8.5501.411.1485469194176165027011125690.3990.3870.6410.744182188252141146196
10.2701.412.86686502672372346110354175960.2760.2680.4430.514231239320180210249
11.8951.614.99419173683313175913727238800.1990.1930.320.371289299400224232310
13.21201.616.2117411494364083991117339301640.1580.1530.2530.294334348467260271362
14.81501.817.7147714505495134950521033377060.1280.1240.2060.239385399633298310412
16.4185220.2176817486606166184626732465030.10210.09910.1640.19448466622247362483
18.6240222.8230522558547987982334679603290.07770.07540.1250.145535558746414432578
20.63002.424.429462886108410169989843400754510.06190.06010.10.11615630865480490630
Two cores3.810111.6228216102896890314050281.9061.833.082.574606078464660
4.8161.214.436234315814010972502480441.1981.151.912.2178283112636487
6.2251.216.8521500217195169307524125680.7490.7271.21.3931101141538689118
7.2351.419.67337043022722346210354176000.540.5240.8681.007136140188106109145
8.5501.422.29699373873523300414202251380.3990.3870.6410.744167173232130134180
10.2701.425.2133613005134834692220708351920.2760.2680.4430.514213220194166193229
11.8951.629.4188218357156626351827454477600.1990.1930.320.371266275368206213285
13.21201.632.2234822978728157982234678603280.1580.1530.2530.294307320430239249333
14.81501.836.229542889109810259901042066754120.1280.1240.2060.239354367490274285380
16.4185240353634561320123112369253466930060.10210.09910.1640.19412429572319333444
18.6240245.44609451017091597159646693561206580.07770.07540.1250.145492513686381397532
20.63002.450.65891577121682032199576866981508220.06190.06010.10.11566580730442451580
Three cores3.810112.5

153134
4950


3.082.574


414153
4.8161.215.5

237209
7536


1.912.217


575778
6.2251.218.1

325292
11286


1.21.393


7680105
7.2351.421.1

453408
15531


0.8681.007


9497130
8.5501.423.9

580528
21033


0.6410.744


116120161
10.2701.427.1

769710
31062


0.4430.514


148172204
11.8951.631.7

1072993
41181


0.320.371


184190254
13.21201.634.7

13081222
52017


0.2530.294


213222297
14.81501.839

16471538
63099


0.2060.239


244254339
16.4185243.1

19811846
81960


0.1640.19


285297396
18.6240248.9

25632395
104037


0.1250.145


339354474
20.63002.454.5

32523047
130047


0.10.11


394402517
Four cores3.810113456434204179133846600100561.9061.833.082.574535370414153
4.8161.216.27216873162802194410048160881.1981.151.912.2177374100575778
6.2251.219.6104010014333903386015048251360.7490.7271.21.393981021367680105
7.2351.422.7146414106045464692420708352000.540.5240.8681.0071211251679497130
8.5501.425.9193618767737066600828044502760.3990.3870.6410.744149154207116120161
10.2701.4302669260110259489384441416703840.2760.2680.4430.514189196262148172204
11.8951.634.6376136721429132712703654908955200.1990.1930.320.371237245328184190254
13.21201.6384692459717441632159644693561206560.1580.1530.2530.294274285383213222297
14.81501.842.65903578221972054198020841321508240.1280.1240.2060.239316327437244254339
16.4185247.270656916264124662476841069281860120.10210.09910.1640.19367382505285297396
18.6240252.692109026341831993192921387162413160.07770.07540.1250.145439458612339354474
20.63002.458.91177011549433540703991521733963016440.06190.06010.10.11504517710394402517


Expand all

Only some product parameters are displayed. For more product information, please contact us.

The above parameters are for reference only.

Cable Structure

10kv Cross-Linked Polyethylene Insulated Overhead Cable

10kv Cross-Linked Polyethylene Insulated Overhead Cable

Features

Features

Conductor material: copper or aluminum

Insulation material: cross-linked polyethylene (XLPE)

Rated voltage: 10kV

Temperature range: -20°C to +75°C (for 10kV cables)

Minimum bending radius: 4D (D < 25mm) / 6D (D ≥ 25mm)

Test voltage: 18kV (12kV for light cables)

Compliant standards: GB/T14049-2008, GB/T12527-2008, IEC standards

Usage Characteristics

Rated voltage is 10KV, 35KV;

Long-term allowable operating temperature of cable conductor: PVC and PE insulation should not exceed 70℃, XLPE insulation should not exceed 90℃;

Maximum temperature of cable during short circuit (maximum duration not exceeding 5s): 250℃ for cross-linked polyethylene insulation, 150℃ for high-density polyethylene insulation; Cable laying temperature should not be lower than -20℃.

Production

Projects

COMMON QUESTIONS

SHENXING Cable Service FAQs

Want to learn more? Check out our electrical cable most frequently asked questions.

What are the application scenarios of 10kV cross-linked polyethylene insulated overhead cable?

10kV cross-linked polyethylene insulated overhead cable is widely used in overhead power transmission systems, especially in power distribution networks, high-voltage power infrastructure, solar photovoltaic power generation systems, street lighting and traffic signal systems in urban and rural areas. It can withstand higher voltages and has excellent weather resistance and long-term stability to ensure the safe operation of the power system.

What is the maximum operating temperature of 10kV cross-linked polyethylene insulated overhead cable?

For cross-linked polyethylene insulated overhead cable with a rated voltage of 10kV, the maximum operating temperature is 75°C (high-density polyethylene insulated cable), and for cross-linked polyethylene (XLPE) insulated cable, the maximum operating temperature is 90°C. This enables it to operate stably in high temperature environments and adapt to various power transmission needs.

Can this cable be used in extreme weather conditions?

Yes, 10kV cross-linked polyethylene insulated overhead cable has good weather resistance and adapts to extreme temperature and humidity conditions. Its operating temperature range is **-20°C to +75°C**, so it can maintain efficient power transmission capabilities even in cold or hot environments. In particular, cross-linked polyethylene (XLPE) insulation provides excellent resistance to UV, oxidation and chemical corrosion.

What are the electrical properties of 10kV cross-linked polyethylene insulated overhead cables?

10kV cross-linked polyethylene insulated overhead cables have excellent electrical properties and can withstand high voltage loads. After a 1-minute voltage test, cables rated at 10kV are subjected to an AC voltage test of 18kV (12kV for light cables) to ensure that the cables have sufficient insulation capacity under high voltage. In addition, the cable insulation layer has been precisely designed to have excellent electrical isolation performance, ensuring that there will be no leakage or short circuit during long-term use.

How to maintain and repair 10kV cross-linked polyethylene insulated overhead cables?

10kV cross-linked polyethylene insulated overhead cables require regular inspection and maintenance. Here are some basic maintenance points:

Regularly check the appearance of the cable to ensure that there is no damage, cracks or wear.

Perform electrical tests regularly to detect whether the insulation performance of the cable is normal.

Clean the dust and debris on the surface of the cable to avoid accumulation of dirt and damage to the cable surface.

Ensure that the cable laying area is kept dry to prevent the humid environment from affecting the long-term stability of the cable.

If the cable is partially damaged, repair or replace it in time to avoid the fault from expanding.

More Frequently Asked Questions.

Related Products

Soft Copper Core Cross-Linked Polyethylene Insulated Overhead Cable

As one of the core products of Shenxing Cable Group, soft copper core cross-linked polyethylene (XLPE) insulated overhead cable is designed for efficient power transmission.

Read More
Soft Copper Core Cross-Linked Polyethylene Insulated Overhead Cable

Aluminum conductor steel reinforced (ascr)Overhead Cable‌

​With the development of power transmission technology and the growth of power grid construction demand, aluminum core polyethylene insulated overhead cables are widely welcomed due to their light weight, corrosion resistance and high cost-effectiveness.

Read More
Aluminum conductor steel reinforced (ascr)Overhead Cable‌

10kv Steel Core Aluminum Cross-Linked Polyethylene Insulated Overhead Cable

The 10kV steel core aluminum conductor cross-linked polyethylene (XLPE) insulated overhead cable provided by Shenxing Cable Group is designed for efficient transmission of overhead power lines. With its sturdy structure and advanced materials, it ensures excellent durability and excellent electrical performance in various power distribution systems.

Read More
10kv Steel Core Aluminum Cross-Linked Polyethylene Insulated Overhead Cable

Request Your Free Electrical Cable Quote Today

After we receive your request, our engineers will immediately analyze your custom part. We proactively work with you to clarify all details, then provide a quote that is both economical and accurate.
GET QUOTE