Medium Voltage(1/35KV) Power-YJLV (Essential for power engineering)
Our medium voltage aluminum core XLPE insulated PVC power cable complies with international standards: IEC 60502, IEC 60228, flame retardant grade: meets IEC 60332-1 requirements. Suitable for medium voltage power systems of 1-35kV. The cable combines high-performance aluminum core conductor, cross-linked polyethylene (XLPE) insulation and polyvinyl chloride (PVC) sheath, suitable for a variety of industrial and municipal applications.
Share:
International Product Name
IEC Standard: Medium Voltage Power Cable (1-35kV) Aluminum Conductor XLPE Insulated Power Cable
BS Standard: BS 7870: Aluminum Conductor XLPE Insulated Power Cable
NEC Standard: Medium Voltage Power Cable with Aluminum Conductor and Aluminum Core XLPE Insulated Power Cable
DIN Standard: DIN VDE 0276: Aluminum Core XLPE Insulated Power Cable
Widely Use:
Power transmission and distribution: widely used in power transmission and distribution of power grids.
Industrial projects: suitable for power transmission in factories, mines and heavy industrial projects.
Municipal and infrastructure: widely used in power supply systems of urban distribution networks, large buildings and commercial facilities.
Advantage:
High rated voltage: The rated voltage covers the range of 1-35kV, which is suitable for various medium voltage distribution systems.
Excellent insulation performance: The XLPE cross-linked polyethylene insulation layer has high insulation resistance and strong breakdown voltage resistance, which effectively prevents leakage and short circuit accidents.
Low loss: Lower resistivity reduces line loss, improves power transmission efficiency, and reduces operating costs.
Good flame retardant performance: The PVC sheath has good flame retardant properties, which can effectively prevent the spread of flames and ensure the safety of electricity use.
Technical Data
Voltage Level: 6/6kv & 6/10kv | ||||||||
Number of Cores | Conductor Diameter | Conductor Diameter | Insulation Thickness | Resistance | Current Carrying Capacity | Sheath Thickness | Cable Outer Diameter | Weight |
(mm) | (mm²) | (mm) | (Ω/Km) | (A) | (mm) | (mm) | (kg/km) | |
Single Core | 6 | 25 | 3.4 | 1.2 | 120/130 | 1.6 | 20.1 | 491 |
7 | 35 | 3.4 | 0.868 | 145/155 | 1.6 | 21.7 | 548 | |
8.3 | 50 | 3.4 | 0.641 | 175/190 | 1.7 | 23 | 628 | |
9.8 | 70 | 3.4 | 0.443 | 215/235 | 1.7 | 24.7 | 732 | |
11.5 | 95 | 3.4 | 0.32 | 255/290 | 1.8 | 26.3 | 847 | |
12.9 | 120 | 3.4 | 0.253 | 290/335 | 1.8 | 27.7 | 957 | |
14.5 | 150 | 3.4 | 0.206 | 330/380 | 1.9 | 29.5 | 1098 | |
16 | 185 | 3.4 | 0.164 | 370/435 | 1.9 | 31.1 | 1241 | |
18.3 | 240 | 3.4 | 0.125 | 435/515 | 2 | 33.5 | 1470 | |
20.5 | 300 | 3.4 | 0.1 | 490/595 | 2.1 | 35.9 | 1715 | |
Three Cores | 6 | 25 | 3.4 | 1.2 | 100/90 | 2.2 | 41.1 | 1549 |
7 | 35 | 3.4 | 0.868 | 120/110 | 2.3 | 43.3 | 1737 | |
8.3 | 50 | 3.4 | 0.641 | 140/130 | 2.4 | 46.3 | 2020 | |
9.8 | 70 | 3.4 | 0.443 | 170/165 | 2.5 | 50.4 | 2414 | |
11.5 | 95 | 3.4 | 0.32 | 210/220 | 2.7 | 54 | 2824 | |
12.9 | 120 | 3.4 | 0.253 | 235/225 | 2.8 | 57.2 | 3217 | |
14.5 | 150 | 3.4 | 0.206 | 260/255 | 2.9 | 60.9 | 3681 | |
16 | 185 | 3.4 | 0.164 | 300/295 | 3 | 66.5 | 4191 | |
18.3 | 240 | 3.4 | 0.125 | 345/345 | 3.2 | 69.7 | 4979 | |
20.5 | 300 | 3.4 | 0.1 | 390/390 | 3.3 | 74.6 | 5788 | |
Voltage level:12/20kV | ||||||||
Single Core | 7 | 35 | 5.5 | 0.868 | 145/155 | 1.8 | 26.6 | 761 |
8.3 | 50 | 5.5 | 0.641 | 175/190 | 1.8 | 27.9 | 849 | |
9.8 | 70 | 5.5 | 0.443 | 215/235 | 1.9 | 29.8 | 979 | |
11.5 | 95 | 5.5 | 0.32 | 255/290 | 1.9 | 31.4 | 1107 | |
12.9 | 120 | 5.5 | 0.253 | 290/335 | 2 | 33 | 1241 | |
14.5 | 150 | 5.5 | 0.206 | 330/380 | 2 | 34.6 | 1382 | |
16 | 185 | 5.5 | 0.164 | 370/435 | 2.1 | 36.4 | 1553 | |
18.3 | 240 | 5.5 | 0.125 | 435/515 | 2.2 | 38.8 | 1803 | |
20.5 | 300 | 5.5 | 0.1 | 490/595 | 2.2 | 41 | 2050 | |
23.5 | 400 | 5.5 | 0.0778 | 565/695 | 2.3 | 45.4 | 2553 | |
Three Cores | 7 | 35 | 5.5 | 0.868 | 120/110 | 2.7 | 54.7 | 2571 |
8.3 | 50 | 5.5 | 0.641 | 140/130 | 2.8 | 57.7 | 2899 | |
9.8 | 70 | 5.5 | 0.443 | 170/165 | 2.9 | 61.5 | 3330 | |
11.5 | 95 | 5.5 | 0.32 | 210/220 | 3 | 65.2 | 3796 | |
12.9 | 120 | 5.5 | 0.253 | 235/225 | 3.1 | 68.4 | 4237 | |
14.5 | 150 | 5.5 | 0.206 | 260/255 | 3.2 | 72 | 4753 | |
16 | 185 | 5.5 | 0.164 | 300/295 | 3.3 | 75.7 | 5319 | |
18.3 | 240 | 5.5 | 0.125 | 345/345 | 3.5 | 80.8 | 6182 | |
20.5 | 300 | 5.5 | 0.1 | 390/390 | 3.7 | 86 | 7103 | |
23.5 | 400 | 5.5 | 0.0778 | 445/450 | 3.9 | 93.2 | 8531 | |
Voltage level:3.6/6kV | ||||||||
Single Core | 6 | 25 | 2.5 | 1.2 | 120/130 | 1.5 | 18.8 | 421 |
7 | 35 | 2.5 | 0.868 | 145/155 | 1.6 | 19.8 | 475 | |
8.3 | 50 | 2.5 | 0.641 | 175/190 | 1.6 | 21.1 | 551 | |
9.8 | 70 | 2.5 | 0.443 | 215/235 | 1.7 | 22.8 | 651 | |
11.5 | 95 | 2.5 | 0.32 | 255/290 | 1.7 | 24.4 | 761 | |
12.9 | 120 | 2.5 | 0.253 | 290/335 | 1.8 | 25.8 | 867 | |
14.5 | 150 | 2.5 | 0.206 | 330/380 | 1.8 | 27.4 | 991 | |
16 | 185 | 2.5 | 0.164 | 370/435 | 1.9 | 29.2 | 1141 | |
18.3 | 240 | 2.6 | 0.125 | 435/515 | 2 | 31.8 | 1374 | |
20.5 | 300 | 2.8 | 0.1 | 490/595 | 2.1 | 34.7 | 1639 | |
Three Cores | 6 | 25 | 2.5 | 1.2 | 100/90 | 2.1 | 36.6 | 1277 |
7 | 35 | 2.5 | 0.868 | 120/110 | 2.2 | 39 | 1469 | |
8.3 | 50 | 2.5 | 0.641 | 140/130 | 2.3 | 42 | 1735 | |
9.8 | 70 | 2.5 | 0.443 | 170/165 | 2.4 | 45.8 | 2085 | |
11.5 | 95 | 2.5 | 0.32 | 210/220 | 2.5 | 49.5 | 2474 | |
12.9 | 120 | 2.5 | 0.253 | 235/225 | 2.6 | 52.7 | 2847 | |
14.5 | 150 | 2.5 | 0.206 | 260/255 | 2.8 | 56.5 | 3311 | |
16 | 185 | 2.5 | 0.164 | 300/295 | 2.9 | 60.2 | 3802 | |
18.3 | 240 | 2.6 | 0.125 | 345/345 | 3 | 65.8 | 4599 | |
20.5 | 300 | 2.8 | 0.1 | 390/390 | 3.2 | 71.8 | 5507 | |
Voltage level:8.7/10kV & 8.7/15kV | ||||||||
Single Core | 6 | 25 | 4.5 | 1.2 | 120/130 | 1.6 | 23.1 | 585 |
7 | 35 | 4.5 | 0.868 | 145/155 | 1.6 | 24.1 | 646 | |
8.3 | 50 | 4.5 | 0.641 | 175/190 | 1.7 | 25.4 | 729 | |
9.8 | 70 | 4.5 | 0.443 | 215/235 | 1.8 | 27.1 | 840 | |
11.5 | 95 | 4.5 | 0.32 | 255/290 | 1.8 | 28.9 | 973 | |
12.9 | 120 | 4.5 | 0.253 | 290/335 | 1.9 | 30.3 | 1087 | |
14.5 | 150 | 4.5 | 0.206 | 330/380 | 1.9 | 32.1 | 1236 | |
16 | 185 | 4.5 | 0.164 | 370/435 | 2 | 33.7 | 1385 | |
18.3 | 240 | 4.5 | 0.125 | 435/515 | 2.1 | 36.1 | 1624 | |
20.5 | 300 | 4.5 | 0.1 | 490/595 | 2.2 | 38.5 | 1879 | |
23.5 | 400 | 4.5 | 0.0778 | 565/695 | 2.3 | 43.1 | 2377 | |
Three Cores | 6 | 25 | 4.5 | 1.2 | 100/90 | 2.4 | 46.4 | 1893 |
7 | 35 | 4.5 | 0.868 | 120/110 | 2.5 | 48.8 | 2116 | |
8.3 | 50 | 4.5 | 0.641 | 140/130 | 2.6 | 54.8 | 2421 | |
9.8 | 70 | 4.5 | 0.443 | 170/165 | 2.7 | 55.6 | 2821 | |
11.5 | 95 | 4.5 | 0.32 | 210/220 | 2.8 | 59.3 | 3257 | |
12.9 | 120 | 4.5 | 0.253 | 235/225 | 2.9 | 62.5 | 3672 | |
14.5 | 150 | 4.5 | 0.206 | 260/255 | 3 | 66.4 | 4190 | |
16 | 185 | 4.5 | 0.164 | 300/295 | 3.2 | 70 | 4726 | |
18.3 | 240 | 4.5 | 0.125 | 345/345 | 3.3 | 75.1 | 5551 | |
20.5 | 300 | 4.5 | 0.1 | 390/390 | 3.5 | 80.1 | 6397 | |
Voltage level:18/20kV & 18/30kV | ||||||||
Single Core | 8.3 | 50 | 0.641 | 175/190 | 2 | 35.1 | 1253 | |
9.8 | 70 | 0.443 | 215/235 | 2.1 | 37 | 1405 | ||
11.5 | 95 | 0.32 | 255/290 | 2.1 | 38.6 | 1550 | ||
12.9 | 120 | 0.253 | 290/335 | 2.2 | 40.2 | 1703 | ||
14.5 | 150 | 0.206 | 330/380 | 2.2 | 41.8 | 1863 | ||
16 | 185 | 0.164 | 370/435 | 2.3 | 43.6 | 2054 | ||
18.3 | 240 | 0.125 | 435/515 | 2.3 | 45.8 | 2312 | ||
20.5 | 300 | 0.1 | 490/595 | 2.4 | 48.2 | 2604 | ||
Three Cores | 8.3 | 50 | 8 | 0.641 | 140/130 | 3.1 | 69 | 4350 |
9.8 | 70 | 8 | 0.443 | 170/165 | 3.2 | 72.5 | 4930 | |
11.5 | 95 | 8 | 0.32 | 210/220 | 3.4 | 77 | 5580 | |
12.9 | 120 | 8 | 0.253 | 235/225 | 3.5 | 80 | 6100 | |
14.5 | 150 | 8 | 0.206 | 260/255 | 3.6 | 83.5 | 6410 | |
16 | 185 | 8 | 0.164 | 300/295 | 3.7 | 87 | 7370 | |
18.3 | 240 | 8 | 0.125 | 345/345 | 3.9 | 92.2 | 8300 | |
20.5 | 300 | 8 | 0.1 | 390/390 | 4 | 97.3 | 9300 | |
23.5 | 400 | 8 | 0.0778 | 445/450 | ||||
Voltage level:21/35kV | ||||||||
Single Core | 8.3 | 50 | 9.3 | 0.641 | 175/190 | 2.1 | 38.1 | 1441 |
9.8 | 70 | 9.3 | 0.443 | 215/235 | 2.1 | 40 | 1602 | |
11.5 | 95 | 9.3 | 0.32 | 255/290 | 2.2 | 41.6 | 1754 | |
12.9 | 120 | 9.3 | 0.253 | 290/335 | 2.2 | 43.2 | 1915 | |
14.5 | 150 | 9.3 | 0.206 | 330/380 | 2.3 | 44.8 | 2082 | |
16 | 185 | 9.3 | 0.164 | 370/435 | 2.3 | 46.6 | 2282 | |
18.3 | 240 | 9.3 | 0.125 | 435/515 | 2.4 | 49.2 | 2570 | |
20.5 | 300 | 9.3 | 0.1 | 490/595 | 2.5 | 51.2 | 2852 | |
Three Cores | 8.3 | 50 | 9.3 | 0.641 | 140/130 | 3.3 | 75.1 | 4640 |
9.8 | 70 | 9.3 | 0.443 | 170/165 | 3.5 | 78.6 | 5160 | |
11.5 | 95 | 9.3 | 0.32 | 210/220 | 3.6 | 82.5 | 5730 | |
12.9 | 120 | 9.3 | 0.253 | 235/225 | 3.7 | 85.7 | 6262 | |
14.5 | 150 | 9.3 | 0.206 | 260/255 | 3.8 | 89.4 | 6860 | |
16 | 185 | 9.3 | 0.164 | 300/295 | 3.9 | 92.8 | 7500 | |
18.3 | 240 | 9.3 | 0.125 | 345/345 | 4.1 | 98.1 | 8520 | |
20.5 | 300 | 9.3 | 0.1 | 390/390 | 4.2 | 103.1 | 9520 |
Expand all
Only some product parameters are displayed. For more product information, please contact us.
The above parameters are for reference only.
Cable Structure
1-35kv Medium Voltage Aluminum Core XLPE Insulated PVC Power Cable
Features
Features
Excellent electrical performance:
Insulation resistance: ≥1000 MΩ/km, ensuring good electrical isolation.
Dielectric strength: ≥20 kV/mm, suitable for high voltage environment.
Temperature resistance:
Operating temperature range: -40°C to 90°C, ensuring stable operation in extreme climates.
Lightweight aluminum core, cost-effective:
Conductor cross-section: The optional range is from 16 mm² to 240 mm², adapting to different load requirements.
Weight: The aluminum core is about 30% lighter than the copper core, which is easy to install and transport.
High safety:
Flame retardant performance: in line with IEC 60332-1 standard, can effectively prevent the spread of fire.
Short circuit withstand capacity: can withstand 3 times the rated current of the maximum short-circuit current to ensure safety.
Usage Characteristics
The maximum rated operating temperature of the conductor is 90℃
The maximum short-circuit temperature of the conductor shall not exceed 250℃
The maximum time shall not exceed 5 seconds
The installation and laying temperature of the cable shall not be lower than 0℃
The laying temperature in the air shall be 40℃
The laying temperature in the soil shall be 25℃.
Minimum bending radius (D is the outer diameter of the cable)
Single core: 20D±5%
Three cores without armor: 15D±5%
Three cores with armor: 12D±5%
Production
Production Equipment
Experimental Equipment
Projects
COMMON QUESTIONS
SHENXING Cable Service FAQs
Want to learn more? Check out our electrical cable most frequently asked questions.
What is the applicable voltage range of this cable?
This cable is suitable for medium voltage power systems from 1kV to 35kV.
What is the difference between aluminum core and copper core cables?
Aluminum core cables are light and low cost, suitable for long-distance power transmission, while copper core cables are more conductive but heavier and more expensive.
What is the operating temperature range of the cable?
The operating temperature range of this cable is -40°C to 90°C, suitable for a variety of environmental conditions.
How is the waterproof performance of the cable?
The cable is designed to meet waterproof standards and is suitable for use in humid environments and underground laying.
What should be paid attention to when installing this cable?
Avoid excessive bending and stretching during installation, and ensure that the cable is used in appropriate environmental conditions to avoid affecting performance.
How is the flame retardant performance of the cable?
This cable complies with the IEC 60332-1 standard, has good flame retardant properties, and effectively reduces the risk of fire.
What is the approximate service life of the cable?
Under normal use and maintenance, the service life of this cable can reach 40 years or more.
If the cable is damaged, how to repair it?
It is generally recommended that repairs or replacements be performed by a professional electrical engineer to ensure safety and performance.
Can this cable be used outdoors?
Yes, the PVC material of the outer sheath is UV-resistant and suitable for outdoor environments.
How to determine the cross-section of the cable?
The selection of the appropriate cross-section should take into account load current, distance and environmental factors. It is recommended to consult a professional for selection.
More Frequently Asked Questions.
Related Products
Request Your Free Electrical Cable Quote Today