1-35kv Power Cable-YJHLV
The medium-voltage YJHLV cable independently developed by Shenxing Cable Group adopts the most advanced manufacturing technology and selected materials. Through rigorous data testing and verification, it has become a trusted key product in the global power transmission system. The cable adopts high-purity copper core and high-temperature resistant and high-strength insulation materials. Under the condition of rated working voltage of 25kV, its current carrying capacity reaches more than 800A, and it can maintain energy loss as low as 0.02% in long-term operation, and its service life is expected to exceed 40 years.
Share:
International standards and certifications:
YJHLV cables are produced and tested in strict accordance with international and domestic standards, and have obtained IEC 60502, IEEE 48, UL 1581, CSA and GB/T 12706 certifications, ensuring that they can meet high standards of safety and reliability in different regions and various application scenarios around the world. In addition, the ISO 9001 and ISO 14001 system certifications fully demonstrate Shenxing Cable Group's continued investment in quality management and environmental protection.
Application areas:
Industrial power distribution system: ensure stable power supply for factories and large industrial parks.
Urban and rural utilities: meet the needs of power network construction in different regions.
Renewable energy projects: support power transmission in various energy forms such as solar energy, wind energy, and hydropower.
High-end infrastructure construction: suitable for key areas such as airports, railways, and smart grid systems.
Its outstanding performance in heat resistance, corrosion resistance, mechanical damage resistance, and high electrical efficiency not only greatly improves system stability, but also significantly reduces maintenance costs and downtime risks, meeting the dual needs of electrical engineers, system integrators, and project managers for long-term economic benefits and technical reliability.
Product advantages:
Excellent durability: high-purity copper core and polymer high-temperature resistant insulation materials are used to ensure stable performance under long-term and high-load operation, with a service life of more than 40 years.
Low energy consumption and high efficiency: energy loss is as low as 0.02%, which greatly improves power transmission efficiency and reduces system operating costs.
Extreme environment resistance: After strict high temperature resistance, corrosion resistance and mechanical stress resistance design, it still maintains excellent electrical and mechanical properties in harsh environments.
Wide applicability: Suitable for medium voltage applications from 1kV to 35kV, meeting the needs of multiple fields such as industry, cities, renewable energy and infrastructure.
Technical Data
Voltage Level: 6/6Kv & 6/10Kv | |||||||||
Number Of Cores | Conductor Diameter | Conductor Diameter | Insulation Thickness | Resistance | Current Carrying Capacity | Sheath Thickness | Armor Thickness | Cable Outer Diameter | Weight |
(mm) | (mm²) | (mm) | (Ω/Km) | (A) | (mm) | (mm) | (mm) | (kg/km) | |
Single Core | 6 | 25 | 3.4 | 1.2 | 120/130 | ||||
7 | 35 | 3.4 | 0.868 | 145/155 | |||||
8.3 | 50 | 3.4 | 0.641 | 175/190 | |||||
9.8 | 70 | 3.4 | 0.443 | 215/235 | |||||
11.5 | 95 | 3.4 | 0.32 | 255/290 | |||||
12.9 | 120 | 3.4 | 0.253 | 290/335 | |||||
14.5 | 150 | 3.4 | 0.206 | 330/380 | |||||
16 | 185 | 3.4 | 0.164 | 370/435 | |||||
18.3 | 240 | 3.4 | 0.125 | 435/515 | |||||
20.5 | 300 | 3.4 | 0.1 | 490/595 | |||||
Three Cores | 6 | 25 | 3.4 | 1.2 | 100/90 | 2.4 | 0.2x2 | 47.3 | 2687 |
7 | 35 | 3.4 | 0.868 | 120/110 | 2.5 | 0.2X2 | 49.7 | 2955 | |
8.3 | 50 | 3.4 | 0.641 | 140/130 | 2.6 | 0.2x2 | 52.7 | 3316 | |
9.8 | 70 | 3.4 | 0.443 | 170/165 | 2.7 | 0.2X2 | 56.6 | 3791 | |
11.5 | 95 | 3.4 | 0.32 | 210/220 | 2.8 | 0.2x2 | 60.2 | 4295 | |
12.9 | 120 | 3.4 | 0.253 | 235/225 | 2.9 | 0.2X2 | 63.4 | 4770 | |
14.5 | 150 | 3.4 | 0.206 | 260/255 | 3.1 | 0.2x2 | 67.1 | 5329 | |
16 | 185 | 3.4 | 0.164 | 300/295 | 3.2 | 0.2X2 | 70.7 | 5932 | |
18.3 | 240 | 3.4 | 0.125 | 345/345 | 3.4 | 0.5x2 | 76.9 | 7028 | |
20.5 | 300 | 3.4 | 0.1 | 390/390 | 3.6 | 0.5x2 | 82 | 8011 | |
Voltage Level:12/20Kv | |||||||||
Single Core | 7 | 35 | 5.5 | 0.868 | 145/155 | ||||
8.3 | 50 | 5.5 | 0.641 | 175/190 | |||||
9.8 | 70 | 5.5 | 0.443 | 215/235 | |||||
11.5 | 95 | 5.5 | 0.32 | 255/290 | |||||
12.9 | 120 | 5.5 | 0.253 | 290/335 | |||||
14.5 | 150 | 5.5 | 0.206 | 330/380 | |||||
16 | 185 | 5.5 | 0.164 | 370/435 | |||||
18.3 | 240 | 5.5 | 0.125 | 435/515 | |||||
20.5 | 300 | 5.5 | 0.1 | 490/595 | |||||
23.5 | 400 | 5.5 | 0.0778 | 565/695 | |||||
Three Cores | 7 | 35 | 5.5 | 0.868 | 120/110 | 2.8 | 0.2x2 | 60.9 | 4052 |
8.3 | 50 | 5.5 | 0.641 | 140/130 | 2.9 | 0.2x2 | 63.9 | 4465 | |
9.8 | 70 | 5.5 | 0.443 | 170/165 | 3.1 | 0.2x2 | 67.9 | 5024 | |
11.5 | 95 | 5.5 | 0.32 | 210/220 | 3.2 | 0.2x2 | 71.6 | 5587 | |
12.9 | 120 | 5.5 | 0.253 | 235/225 | 3.3 | 0.2x2 | 75.8 | 6284 | |
14.5 | 150 | 5.5 | 0.206 | 260/255 | 3.4 | 0.5x2 | 79.4 | 6903 | |
16 | 185 | 5.5 | 0.164 | 300/295 | 3.5 | 0.5x2 | 83.3 | 8422 | |
18.3 | 240 | 5.5 | 0.125 | 345/345 | 3.7 | 0.5x2 | 88.4 | 9480 | |
20.5 | 300 | 5.5 | 0.1 | 390/390 | 3.9 | 0.5x2 | 93.4 | 10559 | |
23.5 | 400 | 5.5 | 0.0778 | 445/450 | 4.2 | 0.5x2 | 102 | 12272 |
Voltage level:3.6/6kV | |||||||||||||||||
Number of cores | Conductor Diameter | Conductor Diameter | Insulation Thickness | Resistance | Current Carrying Capacity | Steel Tape Armoured | Fine steel wire armor | Thick steel wire armor | |||||||||
(mm) | (mm²) | (mm) | (Ω/Km) | (A) | Sheath Thickness(mm) | Armor Thickness (mm) | Cable Outer Diameter (mm) | Weight (kg/km) | Sheath Thickness (mm) | Wire diameter (mm) | Cable Outer Diametermm | Weight kg/km | Sheath Thicknessmm | Wire Diameter mm | Cable Outer Diametermm | Weight kg/km | |
Single Core | 6 | 25 | 2.5 | 1.2 | 120/130 | 1.8 | 1.6 | 26.2 | 1410 | ||||||||
7 | 35 | 2.5 | 0.868 | 145/155 | 1.8 | 1.6 | 27.2 | 1510 | |||||||||
8.3 | 50 | 2.5 | 0.641 | 175/190 | 1.8 | 1.6 | 28.5 | 1645 | |||||||||
9.8 | 70 | 2.5 | 0.443 | 215/235 | 1.9 | 1.6 | 30.4 | 1836 | |||||||||
11.5 | 95 | 2.5 | 0.32 | 255/290 | 1.9 | 1.6 | 32 | 2021 | |||||||||
12.9 | 120 | 2.5 | 0.253 | 290/335 | 2 | 2 | 33.6 | 2205 | |||||||||
14.5 | 150 | 2.5 | 0.206 | 330/380 | 2.1 | 2 | 36.4 | 2741 | |||||||||
16 | 185 | 2.5 | 0.164 | 370/435 | 2.1 | 2 | 38 | 2970 | |||||||||
18.3 | 240 | 2.6 | 0.125 | 435/515 | 2.2 | 2 | 40.6 | 3342 | |||||||||
20.5 | 300 | 2.8 | 0.1 | 490/595 | 2.3 | 2 | 43.5 | 3759 | |||||||||
Three Cores | 6 | 25 | 2.5 | 1.2 | 100/90 | 2.3 | 0.2x2 | 42.8 | 2301 | 2.3 | 4 | 49.2 | 4821 | ||||
7 | 35 | 2.5 | 0.868 | 120/110 | 2.3 | 0.2X2 | 45.2 | 2554 | 2.4 | 4 | 51.6 | 5142 | |||||
8.3 | 50 | 2.5 | 0.641 | 140/130 | 2.4 | 0.5x2 | 48.2 | 2897 | 2.6 | 4 | 54.6 | 5749 | |||||
9.8 | 70 | 2.5 | 0.443 | 170/165 | 2.6 | 0.5x2 | 52 | 3345 | 2.7 | 4 | 58.4 | 6371 | |||||
11.5 | 95 | 2.5 | 0.32 | 210/220 | 2.7 | 0.5x2 | 55.9 | 3854 | 2.8 | 4 | 62.3 | 7109 | |||||
12.9 | 120 | 2.5 | 0.253 | 235/225 | 2.8 | 0.5x2 | 59.1 | 4311 | 2.9 | 4 | 65.5 | 7723 | |||||
14.5 | 150 | 2.5 | 0.206 | 260/255 | 2.9 | 0.5x2 | 62.7 | 4854 | 3 | 4 | 69.1 | 8512 | |||||
16 | 185 | 2.5 | 0.164 | 300/295 | 3.1 | 0.5x2 | 66.4 | 5432 | 3.2 | 4 | 72.8 | 9248 | |||||
18.3 | 240 | 2.6 | 0.125 | 345/345 | 3.2 | 0.5x2 | 72 | 6372 | 3.4 | 4 | 78.4 | 10518 | |||||
20.5 | 300 | 2.8 | 0.1 | 390/390 | 3.4 | 0.5x2 | 79 | 7615 | 3.6 | 4 | 86.4 | 12168 | |||||
Voltage Level:8.7/10Kv & 8.7/15Kv | |||||||||||||||||
Single Core | 6 | 25 | 4.5 | 1.2 | 120/130 | ||||||||||||
7 | 35 | 4.5 | 0.868 | 145/155 | |||||||||||||
8.3 | 50 | 4.5 | 0.641 | 175/190 | |||||||||||||
9.8 | 70 | 4.5 | 0.443 | 215/235 | |||||||||||||
11.5 | 95 | 4.5 | 0.32 | 255/290 | |||||||||||||
12.9 | 120 | 4.5 | 0.253 | 290/335 | |||||||||||||
14.5 | 150 | 4.5 | 0.206 | 330/380 | |||||||||||||
16 | 185 | 4.5 | 0.164 | 370/435 | |||||||||||||
18.3 | 240 | 4.5 | 0.125 | 435/515 | |||||||||||||
20.5 | 300 | 4.5 | 0.1 | 490/595 | |||||||||||||
23.5 | 400 | 4.5 | 0.0778 | 565/695 | |||||||||||||
Three Cores | 6 | 25 | 4.5 | 1.2 | 100/90 | 2.6 | 0.2x2 | 52.8 | 3192 | 2.7 | 2.5 | 57.3 | 5372 | 4 | 2.7 | 59.2 | 6287 |
7 | 35 | 4.5 | 0.868 | 120/110 | 2.6 | 0.2X2 | 55 | 3454 | 2.8 | 2.5 | 59.7 | 5749 | 4 | 2.8 | 61.6 | 6941 | |
8.3 | 50 | 4.5 | 0.641 | 140/130 | 2.8 | 0.2x2 | 58 | 3835 | 2.9 | 2.5 | 62.7 | 6277 | 4 | 2.9 | 64.6 | 7186 | |
9.8 | 70 | 4.5 | 0.443 | 170/165 | 2.9 | 0.2X2 | 62 | 4360 | 3 | 2.5 | 66.5 | 6908 | 4 | 3 | 68.4 | 7936 | |
11.5 | 95 | 4.5 | 0.32 | 210/220 | 3 | 0.2x2 | 65.7 | 4894 | 3.1 | 2.5 | 70.2 | 7574 | 4 | 3.1 | 72.1 | 8722 | |
12.9 | 120 | 4.5 | 0.253 | 235/225 | 3.1 | 0.2X2 | 68.9 | 5393 | 3.2 | 3.15 | 73.4 | 8214 | 4 | 3.2 | 75.3 | 9378 | |
14.5 | 150 | 4.5 | 0.206 | 260/255 | 3.2 | 0.2x2 | 72.6 | 5979 | 3.3 | 3.15 | 77.3 | 9030 | 4 | 3.3 | 79 | 10216 | |
16 | 185 | 4.5 | 0.164 | 300/295 | 3.4 | 0.5x2 | 77.2 | 6784 | 3.5 | 3.15 | 81.9 | 10019 | 4 | 3.5 | 83.8 | 11295 | |
18.3 | 240 | 4.5 | 0.125 | 345/345 | 3.5 | 0.5X2 | 82.3 | 8553 | 3.7 | 3.15 | 4 | 3.7 | 88.7 | 12459 | |||
20.5 | 300 | 4.5 | 0.1 | 390/390 | 3.8 | 0.5x2 | 87.5 | 9629 | 4 | 3.9 | 93.9 | 13820 |
Voltage Level:18/20Kv & 18/30Kv | |||||||||||||
Single Core | 8.3 | 50 | 0.641 | 175/190 | |||||||||
9.8 | 70 | 0.443 | 215/235 | ||||||||||
11.5 | 95 | 0.32 | 255/290 | ||||||||||
12.9 | 120 | 0.253 | 290/335 | ||||||||||
14.5 | 150 | 0.206 | 330/380 | ||||||||||
16 | 185 | 0.164 | 370/435 | ||||||||||
18.3 | 240 | 0.125 | 435/515 | ||||||||||
20.5 | 300 | 0.1 | 490/595 | ||||||||||
Three Cores | 8.3 | 50 | 8 | 0.641 | 140/130 | 3.3 | 0.2x2 | 75.1 | 6250 | 3.5 | 31.5 | 79.7 | 8870 |
9.8 | 70 | 8 | 0.443 | 170/165 | 3.5 | 0.5x2 | 78.7 | 6910 | 3.6 | 31.5 | 83.3 | 9610 | |
11.5 | 95 | 8 | 0.32 | 210/220 | 3.6 | 0.5x2 | 84 | 7620 | 3.7 | 31.5 | 87.4 | 10470 | |
12.9 | 120 | 8 | 0.253 | 235/225 | 3.8 | 0.5X2 | 87.5 | 8870 | 3.9 | 31.5 | 90.8 | 11220 | |
14.5 | 150 | 8 | 0.206 | 260/255 | 3.9 | 0.5x2 | 91.3 | 9580 | 4 | 31.5 | 94.6 | 12100 | |
16 | 185 | 8 | 0.164 | 300/295 | 4 | 0.5x2 | 94.9 | 10450 | 4.1 | 31.5 | 98.2 | 12990 | |
18.3 | 240 | 8 | 0.125 | 345/345 | 4.2 | 0.5x2 | 100.3 | 11590 | 4.3 | 31.5 | 103.7 | 14340 | |
20.5 | 300 | 8 | 0.1 | 390/390 | 4.3 | 0.5X2 | 105.6 | 12850 | |||||
23.5 | 400 | 8 | 0.0778 | 445/450 | 4.6 | 0.5x2 | 112.8 | 14410 | |||||
Voltage Level:21/35Kv | |||||||||||||
Single Core | 8.3 | 50 | 9.3 | 0.641 | 175/190 | 2.3 | 2.5 | 46.9 | 4761 | ||||
9.8 | 70 | 9.3 | 0.443 | 215/235 | 2.4 | 2.5 | 48.8 | 5031 | |||||
11.5 | 95 | 9.3 | 0.32 | 255/290 | 2.5 | 2.5 | 51.9 | 5325 | |||||
12.9 | 120 | 9.3 | 0.253 | 290/335 | 2.5 | 2.5 | 53.3 | 5570 | |||||
14.5 | 150 | 9.3 | 0.206 | 330/380 | 2.6 | 2.5 | 55.1 | 5880 | |||||
16 | 185 | 9.3 | 0.164 | 370/435 | 2.6 | 2.5 | 56.9 | 6179 | |||||
18.3 | 240 | 9.3 | 0.125 | 435/515 | 2.7 | 2.5 | 59.1 | 6635 | |||||
20.5 | 300 | 9.3 | 0.1 | 490/595 | 2.8 | 2.5 | 61.5 | 7108 | |||||
Three Cores | 8.3 | 50 | 9.3 | 0.641 | 140/130 | 3.6 | 0.5x2 | 82.7 | 9335 | ||||
9.8 | 70 | 9.3 | 0.443 | 170/165 | 3.7 | 0.5x2 | 86.3 | 10469 | |||||
11.5 | 95 | 9.3 | 0.32 | 210/220 | 3.8 | 0.5X2 | 90.4 | 10974 | |||||
12.9 | 120 | 9.3 | 0.253 | 235/225 | 4 | 0.5x2 | 93.7 | 11686 | |||||
14.5 | 150 | 9.3 | 0.206 | 260/255 | 4.1 | 0.5x2 | 97.5 | 12550 | |||||
16 | 185 | 9.3 | 0.164 | 300/295 | 4.2 | 0.5x2 | 101.1 | 13464 | |||||
18.3 | 240 | 9.3 | 0.125 | 345/345 | 4.4 | 0.5X2 | 106.6 | 14760 | |||||
20.5 | 300 | 9.3 | 0.1 | 390/390 | 16170 |
Expand all
Only some product parameters are displayed. For more product information, please contact us.
The above parameters are for reference only.
Cable Structure
YJHLV Medium Voltage Aluminum Alloy Power Cable
Features
Technical Specifications
Product Features
Materials and Structure
The high-purity copper core and innovative high-temperature and corrosion-resistant insulation materials are used, and the multi-layer sheath structure design is used to ensure electrical performance and greatly improve the ability to resist mechanical stress. The overall design of the cable takes into account flexibility and rigidity, which is easy to install and maintain.
Design data
2.1 Applicable voltage range: 1kV to 35kV
2.2 Mechanical tensile strength: more than 10kN
2.3 High temperature working conditions: can operate stably under continuous 90°C environment
2.4 Energy loss: as low as 0.02%
User experience
The design fully considers the convenience of installation and maintenance needs, has good flexibility and lightness, reduces the difficulty of on-site construction, and shortens the installation period.
Performance test
Performance test:
1. High voltage tolerance test
During the 120-minute high voltage test, the leakage current of the cable insulation layer was controlled within 0.01mA, ensuring that the product can still operate safely and stably under extreme working conditions.
2. Thermal stability test
After 72 hours of continuous 90°C high temperature test, the performance indicators of the cable did not show obvious attenuation, which fully proved its reliability in high temperature environment.
3. Mechanical strength test
Through bending, stretching and vibration tests, the product showed a tensile strength of more than 10kN and excellent fatigue resistance in actual use, ensuring stability during installation and long-term operation.
4. Environmental adaptation test
The outer sheath of the cable remained intact after cyclic testing in harsh environments such as ultraviolet rays, damp heat and chemical corrosion, proving that it has good environmental adaptability.
Production
Production Equipment
Experimental Equipment
Projects
COMMON QUESTIONS
SHENXING Cable Service FAQs
Want to learn more? Check out our electrical cable most frequently asked questions.
What applications is this cable suitable for?
This cable is mainly suitable for underground power transmission, industrial power distribution, construction projects and energy facilities, especially in environments that require protection and resistance to mechanical damage.
What is the maximum operating temperature of this cable?
The maximum operating temperature of the cable conductor is 70℃, and the maximum temperature of the conductor can reach 160℃ during short circuit, but the duration shall not exceed 5 seconds.
Can this cable be installed in extreme climate conditions?
Yes, the minimum installation and laying temperature of the cable is 0℃. Therefore, it can be installed in low temperature environments, but special protection measures are required when installed in extremely cold environments.
Can the cable be used in water or humid environments?
Yes, the cable has a PVC sheath and steel belt armor, which is waterproof and moisture-proof, and is suitable for buried or humid environments, such as underground cable ducts or moist soil.
What are the temperature requirements for laying the cable in the air and underground?
When laying in the air, the recommended ambient temperature is 40℃; when buried in the soil, the ambient temperature should be 25℃ to ensure the best working performance of the cable.
What are the advantages of using aluminum core instead of copper core?
Aluminum core cable is lighter and less expensive than copper core, suitable for long-distance power transmission projects, and can also meet most industrial and commercial uses in terms of conductivity.
What is the bending radius of the cable?
The bending radius of the cable is usually 15 times its outer diameter. During installation, make sure not to exceed this limit to avoid damaging the internal structure of the cable.
How is the fire resistance of the cable?
The PVC sheath of this cable has a certain degree of fire resistance and flame retardancy under normal conditions, but it is not suitable for use in occasions that require strict fire protection requirements. If there are special fire protection requirements, special fire-resistant cables can be selected.
How long is the life of the cable?
Under standard installation and working conditions, the service life of this cable is generally 25-30 years, depending on environmental conditions and maintenance.
What should be paid attention to during cable construction?
During construction and installation, make sure that the temperature is not lower than 0℃, and comply with the bending radius and mechanical load limits of the cable to avoid damage to the cable during transportation and laying.
More Frequently Asked Questions.